Sampling Scope Draft Specification

This draft is subject to modification

Discuss the changes you would like on our Forum
Input
Characteristic Specification Units
Channels 2
Modes A only, B only, dual trace, added algebraically, XY
Input impedance 50 Ohms
Connector SMA
Sensitivity 2 - 200 mV/division
Dynamic range +/- 1 V
Bandwidth DC to 4 GHz
Risetime 10%-90% 90 ps
DC offset +/- 1 V
Scale accuracy +/- 3 percent
Timebase
Characteristic Specification Units
Sweep Rate range

10

5

ps/division

s/division

Accuracy +/- 3 percent
Triggering
Characteristic Specification Units
Source External or Internal CH1
External input impedance 50 Ohms
External connector SMA
Slope Positive or negative
Bandwidth DC to 4 Ghz
Dynamic range +/- 1 V
Sensitivity +/- 5 mV
Display
Characteristic Specification Units
Type External
Interface HDMI
Resolution 1920 x 1080 Pixels maximum
Software
Item Description
1Auto display amplitude
2Auto triggering
3Auto timebase
4FFT spectral analysis
5Risetime/falltime, 10%-90% and 20%-80%
6Period measurement
7Amplitude measurement
8Bandwidth limitation, high-pass and low-pass
9Comb filter, odd, even, or all harmonics
10Eye diagram with four-point or six-point limits
11Noise rejection by averaging
Environment
Characteristic Specification Units
Ambient Temperature 0 to 50 Celsius
Altitude 3 km Maximum

Last modified: Fri Jun 12 09:54:24 MDT 2015